AF-E 400

Electromagnetic flowmeter for utilities and industrial automation

  • Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
  • Best-in class temperature range, accuracy, pressure drop and flow range
  • Ultra-compact design for parallel installation and tight spaces
  • 4…20 mA, pulse, frequency, Modbus, IO-Link

BATCHFLUX 3100

  • The most compact filling mag meter in the market for filling of conductive liquids, e.g. water, carbonized soft drinks etc.
  • Lightweight, economical design with ceramic flow tube for applications up to 8 bar / 116 psi
  • The DN15 / ½″ ceramic tube conforms to EC1935/2004, FDA, GB 4806
  • Frequency output integrated

BATCHFLUX 5500

  • High accuracy measurement in process batching as well as cold or hot filling of conductive liquids, e.g. milk, fruit drinks with solid content, detergents etc.
  • With ceramic measuring tube and sintered electrodes for applications up to 16 bar / 232 psi
  • Flow tube conforms to EC1935/2004, FDA, GB 4806; 3A certified up to DN25 / 1″
  • Frequency output integrated

OPTIFLUX 1050

Electromagnetic flowmeter for basic applications with conductive liquids

  • Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
  • Extra isolation of electronics for use in high humidity areas
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 1100

Electromagnetic flowmeter for general applications with conductive liquids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 1300

Electromagnetic flowmeter for OEM applications, dosing systems and compact skids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 2050

Electromagnetic flowmeter for basic water and wastewater applications

  • Liner materials resistant to low concentrated chemicals
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 2100

Electromagnetic flowmeter for all standard water and wastewater applications

  • Chemically resistant liner materials
  • Compact version up to IP69, remote version IP68
  • Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 2300

Electromagnetic flowmeter for advanced water and wastewater applications

  • High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
  • 0D/0D installation according to OIML R49 accuracy class 1
  • Flange: DN25…3000 / 1…120″, max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 4050

Electromagnetic flowmeter for basic applications with abrasive and aggressive liquids

  • Chemically resistant liner materials
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN2.5…1200 / ⅒…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 4100

Electromagnetic flowmeter for standard applications with abrasive and aggressive liquids

  • Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…1200 / ⅒…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 4300

Electromagnetic flowmeter for advanced process and custody transfer (CT) applications

  • High accuracy (±0.2%), certified for custody transfer
  • For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
  • Flange: DN2.5…3000 / ⅒…120″, max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 5100

Electromagnetic flowmeter for demanding applications with aggressive and abrasive media

  • With chemically resistant ceramic tube for liquids with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN15…300 / ½…12″, max. PN40 / ASME Cl 300; Sandwich: DN2.5…100 / ⅒…4″
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 5300

Electromagnetic flowmeter for advanced process and master meter applications

  • Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
  • CT: OIML R117, MI-005 etc.
  • Flange: DN15…300 / ½…12″, max. PN40 / ASME Cl 300; Sandwich: DN2.5…100 / ⅒…4″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 6050

  • Cost-effective flow measurement in the food sector
  • Meter size: DN2.5…150 / ⅒…6″ (3A, EHEDG etc.)
  • Many hygienic fittings
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 6100

  • Reliable dosing and filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6″
  • Hygienic fittings and certifications
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 6300

Electromagnetic flowmeter for advanced hygienic applications

  • High accuracy (±0.2%), for exact dosing or filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6″ (3A, EHEDG certified)
  • Many hygienic fittings
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 7300

Electromagnetic flowmeter for low conductivity liquids (≥0.05 μS/cm)

  • Ceramic tube with non-wetted electrodes for extremely adhesive and abrasive media
  • Hygienic and vacuum resistant
  • Flange or wafer/sandwich version: DN25…100 / 1…4″, max. PN40 / ASME Cl:300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

WATERFLUX 3050

Electromagnetic flowmeter for basic water applications

  • Cost-effective measurement of potable, raw and irrigation water
  • Extra isolation of electronics for use in high humidity areas
  • Flange: DN25…600 / 1…24″, max. PN16 / ASME Cl 150; others on request
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

WATERFLUX 3070

Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement

  • Battery- or mains powered, with battery backup option (incl. Modbus)
  • Integrated temperature and pressure measurement for leak monitoring
  • CT: MI-001, OIML R49 up to DN600 / 24″, no inlet/outlet runs needed
  • Burial installation possible (IP68)

WATERFLUX 3100

Electromagnetic flowmeter for standard water applications

  • From raw water measurement to drinking water metering in distribution networks
  • No inlet/outlet runs needed
  • Up to DN600 / 24″, max. PN16 / ASME Cl 150
  • 4…20 mA, pulse, frequency, status, HART®

WATERFLUX 3300

Electromagnetic flowmeter for advanced water applications

  • High accuracy (±0.2%) for water consumption metering and distribution networks
  • No inlet/outlet runs needed
  • CT: MI-001, OIML R49 up to DN600 / 24″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

TIDALFLUX 2300

Electromagnetic flowmeter for applications with partially filled pipes

  • With integrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)
  • Accurate (±1%) and cost-saving alternative to open channel systems
  • Flange: DN200…1600 / 8…64″
  • 3 x 4…20 mA, pulse, HART®, Modbus, PROFINET

FLEXMAG 4050

Electromagnetic flowmeter for single use biopharmaceutical applications

  • With gamma sterilisable disposable flow tube
  • One transmitter accommodates two flow tube diameters
  • Wetted material compliant with ISO 10993 and USP Class VI
  • High accuracy (±1% of MV), wide measuring range, no recalibration

DWM 2000

Electromagnetic insertion-type flowmeter for flow monitoring of conductive media

  • Ideal for liquids, pastes and slurries (≥20μS/cm), suitable for immersed applications (IP68)
  • -25…+150°C / -13…+302°F; up to 25 barg / 360 psig
  • For pipes DN25…400 / 1…16″, optional >DN400 / 16″
  • 3-wire, 4…20 mA

OPTIPROBE

Electromagnetic insertion-type flowmeter for water and wastewater applications

  • With fixed or flexible installation length for hot tapping
  • 0…+100°C; max. 16 barg
  • For pipes ≥DN80 / 3″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 4030

  • Designed and tested for industrial nuclear environments
  • DN25…1000 / 1…40″; with resistant ETFE or PFA liner materials
  • Free of programmable electronic components
  • 4…20 mA

POWERFLUX 4300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With resistant ETFE or PFA liner materials
  • Flange: DN25…1000 / 1…40″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 5030

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube (DN2.5…100 / 1⁄10…4″) for very aggressive and abrasive fluids
  • Free of programmable electronic components
  • 4…20 mA

POWERFLUX 5300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube for very aggressive and abrasive fluids
  • Space-saving wafer design: DN2.5…100 / 1⁄10…4″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIGAS 4010

Coriolis mass flowmeter for gas dispenser applications

  • High accuracy for CNG and LPG up to 70 kg/min / 155 lb/min
  • Thread: ¾ NPT (female); up to 350 bar / 5075 psi
  • Integrated Modbus, no separate converter
  • EtherNet/IP™ interface

OPTIBATCH 4011

Coriolis mass flowmeter for linear and rotating filling machines

  • High accuracy batching of conductive and non-conductive liquids
  • Meter size: DN8…15 (FDA, EC1935/2004 etc.)
  • Many hygienic fittings
  • Integrated Modbus

OPTIBATCH 4011

OPTIMASS 1010

Coriolis mass flowmeter for universal applications and process control

  • For mass, density and volume flow of liquids and gases up to +130°C / +266°F
  • Also certified for hygienic use
  • Flange: DN15…100 / ½…4″, max. PN100 / ASME Cl 600; many hygienic fittings
  • Integrated Modbus; optional EtherNet/IP™ interface

OPTIMASS 1400

Coriolis mass flowmeter for universal applications and process control

  • Mass, density and volume flow of gases and liquids; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • Also certified for hygienic use
  • Flange: DN15…100 / ½…4″, max. PN100 / ASME Cl 600; many hygienic fittings
  • 3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 2400

Coriolis mass flowmeter for highest capacity bulk measurement

  • For gases and liquids up to 4,600 t/h; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • CT: OIML R117, MI-005, MI-002; API and AGA compliant
  • Flange: DN100…400 / 4…16″, max. PN160 / ASME Cl 1500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 3010

Coriolis mass flowmeter for low flow and dosing applications

  • Mass, density and volume flow of liquids and gases (>0.3 kg/h / 0.01 lb/min)
  • Standard pressure rating up to 300 bar / 4351 psi
  • Flange: DN15 / ½”; thread, clamp, etc.
  • Integrated Modbus; optional EtherNet/IP™ interface

OPTIMASS 3400

Coriolis mass flowmeter for low flow and dosing applications

  • High accuracy (±0.1%) for gases and liquids >0.3 kg/h / 0.01 lb/min; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • Standard pressure rating up to 300 bar / 4351 psi
  • Flange: DN15 / 1/2“; also thread and clamp connections
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 6400

Coriolis mass flowmeter for advanced process applications

  • High accuracy (±0.05% flat), for cryogenic to HT media (-200…+400°C / -328…+752°F); maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • SIL 2/3; CT: OIML R117, R137, MI-005, MI-002; API, AGA; hygienic certifications
  • Flange: DN10…300 / ½…12″, max. PN 160 / ASME Cl 1500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 7010

Coriolis mass flowmeter for advanced applications and process control

  • Single straight tube for mass, density and volume flow of viscous, aggressive or shear-sensitive media
  • Also certified for hygienic use
  • Flange: DN10…100 / ½…4″, max. PN100 / ASME Cl 600; others
  • Integrated Modbus; optional EtherNet/IP™ interface

OPTIMASS 7400

Coriolis mass flowmeter for advanced process applications

  • High accuracy (±0.1%), for viscous, aggressive or shear-sensitive media; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • CT: OIML R117, MI-005; API; hygienic certifications
  • Flange: DN10…100 / ½…4″, max. PN100 / ASME Cl 600; others
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTISWIRL 2100

Vortex flowmeter for basic utility applications

  • For liquids, (wet) gases, saturated and superheated steam (+240°C / +464°F)
  • Available with integrated nominal diameter reduction for a large measurement span also in pipelines with large diameters
  • Flange: DN15…300 / ½…12″; wafer version: max. DN100 / 4″
  • 2-wire, 4…20 mA, HART®7

OPTISWIRL 4200

Vortex flowmeter for utility applications and energy management systems

  • For liquids, (wet) gases, saturated and superheated steam (+240°C / +464°F)
  • Integrated P+T measurement: direct output of mass, nominal flow, energy, gross/net heat
  • Flange: DN15…300 / ½…12″; wafer version: max. DN100 / 4″
  • 2-wire, 4…20 mA, HART®, FF, Profibus-PA

OPTISWIRL 5080

Vortex flowmeter for high temperature applications

  • For liquids, gases and steam up to +427°C / +800°F
  • Adaptive filtering and signal conditioning
  • Flange: DN15…300 / ¾…12″, max. PN160 / ASME 1500 lb;
    Sandwich version: max. DN200 / 8″
  • 2-wire, 4…20 mA, HART®

OPTISONIC 3400 District Heating

Ultrasonic flowmeter for district heating applications

  • 3-path meter for thermal energy measurement and heated water
  • CT: OIML R75, MID MI-004 (Class 1, 2, 3)
  • Flange: DN25…2000 / 1…80″, max. PN40 / ASME Cl 300
  • Max. +180°C / +356°F

OPTISONIC 3400

Ultrasonic flowmeter for liquid process applications

  • Accurate 3-path meter: large dynamic range, maintenance-free, no pressure loss
  • Cryogenic (-200°C/-328°F) and HT (+250°C/+482°F) versions; viscosities up to over 1000 cSt
  • Flange: DN25…3000 / 1…120″, max. PN200 / ASME Cl 1500; also weld-ends
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP

OPTISONIC 6300

Ultrasonic clamp-on flowmeter for flow measurement of liquids

  • Stationary device, for installation at any location without process interruption or need to cut pipes
  • Up to +200°C / +392°F
  • Robust stainless steel sensor rail for pipes DN15…4000 / ½…160″
  • 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

OPTISONIC 6300 P

Ultrasonic clamp-on flowmeter for temporary flow measurement of liquids

  • Portable, battery-powered meter, for on-site verification of process flows or inline meters at any location
  • -40…+120°C / +248°F
  • For pipes DN15…1500 / ½…60″
  • With data logger and USB interface for data transfer

OPTISONIC 7300

Ultrasonic flowmeter for natural gas, process gas and utility gas applications

  • 2-path meter, for standard volume flow metering, independent of media properties
  • No maintenance, no pressure loss, large dynamic range
  • Flange: DN50…1000 / 2…40″, max. PN450 / ASME Cl 2500; also weld-in connections
  • 3 x 4…20 mA, HART®, Modbus, FF

OPTISONIC 7300 Biogas

Ultrasonic flowmeter for biogas, landfill and sewage gas applications

  • 1- or 2-path meter for low-pressure biogas (dry or wet) with a high CO2 content
  • Integrated gas volume correction and methane content measurement
  • Lap joint flange: DN50…200 / 2…8″, max. PN10 / ASME Cl 150
  • Large turndown ratio (100:1)

OPTISONIC 8300

Ultrasonic flowmeter for superheated steam and high temperature gases

  • 2-path meter with optional mass flow and enthalpy calculation
  • For steam billing, boiler or power plant monitoring (up to +620°C / +1148°F)
  • DN100…1000 / 4…40″; max. PN250 / ASME Cl 2500
  • Large turndown ratio (60:1)

ALTOSONIC III

Ultrasonic flowmeter for custody transfer (CT) measurement of liquid hydrocarbons

  • Multipath inline flowmeter for light crude oils and refined products
  • CT: OIML R117, MI-005, API, GOST etc.
  • Flange: 2…40″; max. ASME Cl 900
  • -200…+220°C / -328…+364°F

ALTOSONIC 5

Ultrasonic flowmeter for custody transfer (CT) measurement in upstream and midstream applications

  • Multipath inline meter for crudes, refined products, cryogenic media and chemicals
  • CT: OIML R117, API compliant
  • Flange: 4…24″; max. ASME Cl 600
  • -200…+250°C / -328…+482°F

ALTOSONIC V12

Ultrasonic flowmeter for custody transfer (CT) measurement of gases

  • 12-chord meter, for high accuracy flow metering of natural gas
  • CT: OIML R137 (class 0.5), MI-002, AGA9 etc.
  • Many variants, extensive CBM diagnostics free of charge
  • Flange: DN100…1600 / 4…64″; max. PN450 / ASME Cl 2500

OPTISONIC 4400 HT

Ultrasonic flowmeter for high temperature liquids

  • 2-path meter for flow measurement of thermal oil, boiler feed water, crudes and hot feed flows in refineries
  • Up to +600°C / +1112°F
  • Flange: max. DN1000 / 40″
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

OPTISONIC 4400 HP

Ultrasonic flowmeter for high pressure liquids

  • 2-path meter for flow measurement of condensate, high pressure feedwater, spray water or water injection
  • Operating pressure up to 490 bar / 7107 psi
  • Max. DN1000 / 40″, up to ASME Cl 4500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

K20

Variable area flowmeter for basic water applications

  • Plastic tube with scale and a MIN/MAX switch
  • Very cost-effective flow indication
  • Thread: G½, G1, G2; or adhesive sleeve
  • 0…+100°C / +32…+212°F; max. 10 barg / 145 psig

GA24

Variable area flowmeter for low liquid and gas flows

  • Glass tube with easy-to-read scale, MIN/MAX switches
  • Rugged steel plate housing for higher process safety
  • Flange: DN15…50 / ½…2″, max. PN40 / ASME Cl 300
  • -20…+100°C / -4…+212°F

VA40

Variable area flowmeter for basic applications

  • With glass tube, MIN/MAX switches and 4…20 mA
  • Low pressure loss for gas applications
  • Flange: DN15…50 / ½…2″; also NPT, G, hygienic connections, etc.
  • -20…+100°C / -4…+212°F; max. 10 barg / 145 psig

VA45

Variable area flowmeter for low pressure gas applications

  • Glass tube with easy-to-read scale
  • For use in gas supply lines of furnaces, protective gas or heating systems
  • Flange: DN15…40 / ½…1½”; also NPT, G, hose connection
  • -20…+100°C / -4…+212°F; max. 1 barg / 14.5 psig

DK32/34

Variable area flowmeter for low liquid and gas flows

  • Compact mechanical indicator, optional 4…20  mA/HART®7, MIN/MAX switches and needle valve
  • Sturdy metal design: stainless steel or alloy
  • Thread: G¼, ¼ NPT, etc.
  • -40…+200°C / +392°F, max. 220 barg / 3190 psig

DK37 M8

Variable area flowmeter for advanced low liquid and gas flows

  • Mechanical or with electronic indicator (4…20 mA/HART®)
  • Sturdy metal design: stainless steel or alloy
  • Thread: G¼, ¼ NPT; others
  • -40…+150°C / +302°F; max. 220 barg / 3190 psig

DK46/47/48/800

Variable area flowmeter for low flow gas or liquid applications and sample flow monitoring

  • Glass tube with analogue scale, valve and switches
  • For low flows from ≥0.04 l/h or ≥0.1 GPH
  • G and NPT threads; others on request
  • -5…+100°C / +23…+212°F; max. 10 barg / 145 psig

DK700

Variable area flowmeter for low liquid and gas flows

  • Compact glass tube meter with easy-to-read scale and valve
  • For low flows: ≥2.5 l/h or >0.01 GPH
  • Thread: G⅛; others on request
  • -5…+100°C / +23…+212°F; max. 4 barg / 58 psig

H250 M8

Variable area flowmeter for liquids and gases

  • Mechanical or with electronic bargraph indicator (4…20 mA/HART®)
  • Flange: DN15…25 / ½…1″; also NPT, G, hygienic connections, etc.
  • -40…+200°C / +392°F; max. 145 barg / 2102 psig

H250 M40

Variable area flowmeter for liquids and gases

  • Modular design: from mechanical indicator to 4…20 mA/HART®7, FF, Profibus-PA and totalizer
  • Any installation position: vertical, horizontal or in fall pipes
  • Flange: DN15…150 / ½…6″; also NPT, G, hygienic connections, etc.
  • -196…+400°C / -320…+752°F; max. 1000 barg / 14500 psig

OPTIBAR DP 7060

DP flowmeter for volume flow measurement of liquids, gases and steam

  • From basic to engineered versions for challenging flow conditions
  • -270…+400°C / -454…+752°F possible; max. 160 bar / 2320.1 psi
  • Size: optional DN100…3000 / 4…120″
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For basic to very demanding aggressive, abrasive or viscous media
  • Up to +400°C / +752°F; max. 160 bar / 2320.1 psi (line pressure)
  • Flange: DN50…600 / 2…24″
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For small line sizes
  • Up to +400°C / +752°F; max. 160 bar / 2320.1 psi; (line pressure)
  • Sizes: DN15…100 / ¾…2″
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060

DP flowmeter for volume flow measurement of liquids, gases and steam

  • From basic to engineered versions
  • Cryogenic to high temperatures possible (-200…+1000°C / -328…1832°F); max. 160 bar / 2320.1 psi (line pressure)
  • Line sizes from DN50…2000 / 2…80″ (larger on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTITEMP TRA-TF31

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • DIN-style based on form 4F, barstock thermowell with tapered tip
  • -40…+600°C / +1100°F
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
Filter by Categories
Career
News