OPTITEMP TRA-TW59

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Weld-in connection
  • ASME-style, barstock thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TW58

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Weld-in connection
  • ASME-style, barstock thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS54

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • ASME-style, barstock thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS53

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • ASME-style, barstock thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS52

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • ASME-style, barstock thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS37

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • DIN-style based on form 9, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS36

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • DIN-style based on form 7, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS35

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • DIN-style based on form 8, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TS32

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • DIN-style based on form 5, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TF57

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • ASME-style, barstock thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TF56

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • ASME-style, barstock thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TF55

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • ASME-style, barstock thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-T30

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Weld-in connection
  • DIN-style based on form 4, barstock thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-S50

Resistance (RTD) temperature assembly for use in existing thermowells or machinery

  • Thread connection
  • ASME-style, without thermowell
  • -40…+600°C / +1100°F

OPTITEMP TRA-S41

Resistance (RTD) temperature assembly for standard applications

  • Thread connection
  • DIN-style based on form 3G, welded multipart thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-S34

Resistance (RTD) temperature assembly for use in existing thermowells or machinery

  • Thread connection or union nut
  • DIN-style, without thermowell
  • -40…+600°C / +1100°F

OPTITEMP TRA-S22

Resistance (RTD) temperature assembly for standard applications

  • Thread connection
  • DIN-style based on form 2G, welded multipart thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-S21

Resistance (RTD) temperature assembly for lower temperature applications

  • Thread connection
  • DIN-style based on form 8, welded multipart thermowell with reduced tip
  • -40…+150°C / +302°F

OPTITEMP TRA-S11

Resistance (RTD) temperature assembly for lower temperature applications

  • Thread connection
  • DIN-style based on form 8, welded multipart thermowell with straight tip
  • -40…+150°C / +302°F

OPTITEMP TRA-P40

Resistance (RTD) temperature assembly for standard applications

  • Compression fitting connection
  • DIN-style based on form 3, welded multipart thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-P14

Resistance (RTD) temperature assembly for standard applications or use in existing thermowells

  • Compression fitting connection
  • DIN-style, without thermowell
  • -40…+600°C / +1832°F

OPTITEMP TRA-H20

Resistance (RTD) temperature assembly for hygienic applications

  • Hygienic clamp or VARIVENT® connection
  • Replaceable measuring insert and stainless steel thermowell (FDA, EC1935/2004 conform)
  • -200…+600°C / -330…+1100°F

OPTITEMP TRA-H10

Resistance (RTD) temperature assembly for hygienic applications

  • Hygienic clamp or VARIVENT® connection
  • Non-replaceable measuring insert and stainless steel thermowell (FDA, EC1935/2004 conform)
  • -50…+200°C / -58…+390°F

OPTITEMP TRA-G10

Resistance (RTD) temperature assembly for surface temperature measurement in industrial applications

  • Hose clamp connection
  • Spring-loaded block tip, neck tube and stainless steel sheath
  • -50…+200°C / -58…+390°F

OPTITEMP TRA-F23

Resistance (RTD) temperature assembly for standard applications

  • Flange connection
  • DIN-style based on form 2F, welded multipart thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-F13

Resistance (RTD) temperature assembly for standard applications

  • Flange connection
  • DIN-style based on form 2F, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-H61

Resistance (RTD) temperature assembly for hygienic applications

  • G½ thread with VARIVENT®, DIN 11851, SMS 1145 and other hygienic adapters
  • Stainless steel thermowell with reduced tip (FDA, EC1935/2004 conform; optional IP69)
  • -50…+200°C / -58…+390°F

OPTITEMP TRA-H65

Resistance (RTD) temperature assembly for hygienic applications

  • Welded clamp connection
  • Stainless steel thermowell with reduced tip (3A certified, FDA, EC1935/2004 conform; optional IP69)
  • -50…+200°C / -58…+390°F

OPTITEMP TRA-G20

Resistance (RTD) temperature assembly for surface temperature measurement on double-walled pipes or similar applications

  • Thread connection
  • Long spring-loaded straight tip, neck tube and stainless steel sheath
  • -50…+150°C / -58…+300°F

OPTITEMP TRA-F42

Resistance (RTD) temperature assembly for standard applications

  • Flange connection
  • DIN-style based on form 3F, welded multipart thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-P10

Resistance (RTD) temperature assembly for standard applications

  • Compression fitting connection
  • DIN-style based on form 2, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-P20

Resistance (RTD) temperature assembly for standard applications

  • Compression fitting connection
  • DIN-style based on form 2, welded multipart thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-H30

Resistance (RTD) temperature assembly for hygienic applications

  • Hygienic clamp or VARIVENT® connection
  • Non-replaceable measuring insert and stainless steel sensor sheath (FDA, EC1935/2004 conform)
  • -40…+150°C / +302°F

OPTITEMP TRA-S12

Resistance (RTD) temperature assembly for standard applications

  • Thread connection
  • DIN-style based on form 2G, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TF33

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • Welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TF31

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • DIN-style based on form 4F, barstock thermowell with tapered tip
  • -40…+600°C / +1100°F
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
Filter by Categories
Career
News