SENSOFIT FLOW 2000 Y

Flow-through assembly for water and wastewater applications

  • For use with oxygen sensor OPTISENS ADO 2000
  • Sensor connection: Adapter with DN32 union nut; Process connection: DN50 cemented socket connection
  • For inline measurement at 180° flow direction
  • Max. +50°C / +122°F and 1 bar / 14.5 psi

SENSOFIT FLOW 2000 T

Flow-through assembly for water and wastewater applications

  • For use with optical oxygen sensors (OPTISENS ODO 2000)
  • Process connection: cemented socket connection 1½”
  • For inline measurement at 180° flow direction
  • Max. +50C / +122°F and 6 bar / 87 psi

SENSOFIT FLOW 1000 Y

Flow-through assembly for chemical and water treatment applications

  • For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
  • Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
  • For inline measurement at 180°Flow direction
  • Max. +95°C / +203°F and 10 bar / 145 psi

SENSOFIT FLOW 1000 T

Flow-through assembly for chemical and water treatment applications

  • For use with OPTISENS IND 1000 inductive conductivity sensor
  • Sensor connection: G1½ (union nut); Process connection: Socket weld DN32, 40, 50
  • For inline measurement at 180°Flow direction
  • Max. +90°C / +194°F and 10 bar / 145 psi

SENSOFIT IMM 2920

Immersion assembly for chemical and wastewater treatment applications

  • For use with Ø12 / 120 mm (Ø0.47 / 4.7″) sensors or sensors with ¾ NPT
  • Sensor connection: PG13.5 or ¾ NPT (female); Process connection: Flange DN50 / 2″ or suspended holder
  • Immersion length: 1 or 2 m / 39.37″ or 78.74″
  • Max. +80°C / +176°F and 4 bar / 58 psi

SENSOFIT IMM 2000

Immersion assembly for general water and wastewater treatment applications

  • For use with OPTISENS ODO/ADO/TUR 2000, TSS 3000 or sensors with NPT thread
  • Sensor connection: ¾ NPT, 1¼ NPT (female); Process connection: Telescopic rod holder mounted to handrail
  • Immersion length: flexible, max. 4 m / 13.1 ft
  • Max. +60°C / +140°F, pressureless

SENSOFIT IMM 1000

Immersion assembly for general water and wastewater treatment applications

  • For use with OPTISENS COND 1200 or ∅12 / 120 mm and ∅0.47 / 4.7″ sensors
  • Sensor connection: PG13.5 or G½ (female); Process connection: immersion
  • Immersion length: 1 m / 39.37″
  • Max. +80°C / +176°F, pressureless

SENSOFIT INS 7311

Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
  • Sensor connection: PG13.5; Process connection: Tri-Clamp 1″, 1½”, 2″
  • Insertion length: 45 mm / 1.77″
  • Max. +140°C / +284°F and 10 bar / 145 psi

SENSOFIT INS 1310

Insertion assembly for all-purpose applications in various industries

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 70 mm / 2.75″
  • Max. +140°C / +284°F and 10 bar / 145 psi

SENSOFIT INS 1000

Insertion assembly for analytical sensors in process applications

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors (pH, ORP etc.)
  • Sensor connection: PG13.5; Process connection: ¾ or 1 NPT
  • Insertion length: 28 or 53 mm / 1.1 or 2.09″
  • Max. +140°C / +284°F and 12 bar / 174 psi

SENSOFIT RET 5810

Manual retractable assembly for harsh chemical and water treatment applications

  • For use with Ø12 / 225 mm or Ø0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
  • Sensor connection: PG13.5; Process connection: Flange DN32, 40, 50 / 2″
  • Insertion length: 107 mm / 4.21″
  • Max. +140°C / +284°F and 16 bar / 232 psi

SENSOFIT RAM 5830

Automatic retractable assembly for hygienic applications in the food, beverage and pharmaceutical industry

  • For use with ∅12 / 225 mm or ∅0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 107 mm / 4.21″
  • Max. +140°C / +284°F and 16 bar / 232 psi

SENSOFIT RAM 5810

Automatic retractable assembly for harsh chemical and water treatment applications

  • For use with ∅12 / 225 mm or ∅0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
  • Sensor connection: PG13.5; Process connection: DN32, 40, 50 / 2″
  • Insertion length: 107 mm / 4.21″
  • Max. +140°C / +284°F and 16 bar / 232 psi

OPTISYS SLM 2100

Optical sludge level measuring system for sedimentation profile measurement and continuous tracking of sludge blanket

  • Integrated electronics with 2 x 4…20 mA, 3 relays (e.g. for limit switches)
  • 3 measurement modes: profile, sludge blanket/ fluff levels, zone tracking; automatic change of modes possible
  • 0.1…30 g/l; max. 10  m / 32.8 ft
  • Optional automatic flush cleaning unit for low maintenance

OPTISYS TUR 1060

Optical turbidity measuring system for potable water applications

  • 4-wire, 4…20 mA, 2 alarm relays or Modbus via RS485; built-in data logger
  • For online bypass installation
  • 0…100/1000 NTU/FNU; max. +50°C / +122°F; 7 bar / 101 psi
  • 90° scattered infrared light (ISO 7027) or white light (US EPA 180.1)

OPTISENS TUR 2000

Optical turbidity sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…4/40/400  NTU/FNU; Max. +50°C / +122°F; 6 bar / 87 psi
  • 90° scattered light (NIR-LED) measurement acc. to ISO 7027

OPTISYS CL 1100

Potentiostatic amperometric disinfectant measuring system for water and wastewater applications

  • Completely mounted with MAC 100 analytical transmitter (Output: 3 x 4…20 mA)
  • Pre-installed and tested; for bypass lines
  • Cl2: 0.03…20 mg/l; ClO2: 0.05…5 mg/l; O3: 0.05…5 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
  • With chlorine sensor, valves, flow cells, optional pH sensor

OPTISENS CL 1100

Potentiostatic amperometric disinfectant sensor for water and wastewater applications

  • For use with MAC 100 analytical transmitter
  • Process connection: PG13.5
  • Cl2: 0.03…20 mg/l; ClO2: 0.05…5  mg/l; O3: 0.05…5 mg/l; Max. +70°C / +158°F; 6 bar / 87 psi
  • Membrane-free sensor with 2 gold electrodes and sensor cleaning feature

OPTISENS ODO 2000

Optical oxygen sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA or Modbus for direct connection to a PCS; calibration and configuration via Modbus or with MAC 100 transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max +50°C / +122°F; 6 bar / 87 psi
  • With rugged PVC sensor body, available with spray cleaning nozzle (immersion version)

OPTISENS ADO 2000

Amperometric oxygen sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
  • With stainless steel sensor body, rugged PTFE membrane, exchangeable electrode cartridge and temperature compensation

OPTISYS TSS 4050

Total suspended solids system for hygienic applications

  • 4-wire, 4…20 mA, with head-mounted transmitter
  • Process connection: PG13.5
  • Max.: 3 AU, 6 OD, 13000 FAU, 13000 FTU, 3250 EBC, 26.65 g/l; +90°C / +194°F; 10 bar / 145 psi
  • Hygienic stainless steel design, CIP/SIP cleanable

OPTISYS TSS 3050

Total suspended solids system for hygienic applications

  • 4-wire, 4…20 mA, with head-mounted transmitter
  • Process connection: G½ for hygienic adapters
  • Max.: 3  AU, 6 OD, 13000 FAU, 13000 FTU, 3250 EBC, 26.65 g/l, +90°C / +194°F; 10 bar / 145 psi
  • Hygienic stainless steel design, CIP/SIP cleanable

OPTISYS TSS 2050

Total suspended solids system for hygienic applications

  • 4-wire, 4…20 mA, with head-mounted transmitter
  • Process connection: PG13.5
  • Max.: 500  EBC, 2000 FAU, 5.0 g/l, 0.4% TS; +90°C / +194°F; 10 bar / 145 psi
  • Hygienic stainless steel design, CIP/SIP cleanable

OPTISYS TSS 1050

Total suspended solids system for hygienic applications

  • 4-wire, 4…20 mA, with head-mounted transmitter
  • Process connection: G½ for hygienic adapters
  • Max.: 500  EBC, 2000 FAU, 5.0 g/l, 0.4% TS; +90°C / +194°F; 10 bar / 145 psi
  • Hygienic stainless steel design, CIP/SIP cleanable

OPTISENS TSS 7000

Optical total suspended solids sensor for hygienic applications

  • For use with MAC 300 analytical transmitter
  • Process connection: Tri-Clamp 2″, 3″; VARIVENT® N
  • 0…1.5, 20 or 40% milk fat; Max. +85°C / +185°F; 10 bar / 145 psi
  • PP or PVDF sensor using 4-beam alternating light principle, no optical windows, glass free

OPTISENS TSS 3000

Optical total suspended solids sensor for wastewater applications

  • For use with MAC 300 analytical transmitter
  • Process connection: 1¼ NPT (male)
  • 0…2.5, 10 or 25 g/l (sludge); Max. +85°C / +185°F; 10 bar / 145 psi
  • PP sensor using 4-beam alternating light principle, no optical windows, glass free

OPTISENS TSS 2000

Optical total suspended solids sensor for wastewater applications

  • For use with MAC 100 analytical transmitter
  • For immersion
  • 0…4 AU, 0…18.5 g/l (sludge); max. +70°C / +158°F; 1 bar / 14 psi
  • Robust stainless steel sensor using single beam (180° NIR LED) principle, with optical sapphire glass windows

OPTISYS IND 8100

Inductive conductivity measuring system for food and beverage applications

  • 4-wire, 4…20 mA, with head-mounted or remote transmitter
  • Process connection: G1 for hygienic adapters
  • 0.05…1000 mS/cm; Max. +140°C / +285°F; 10 bar / 145 psi
  • Hygienic PEEK sensor, robust (IP69K), with temperature compensation

OPTISYS IND 7100

Inductive conductivity measuring system for food and beverage applications

  • 4-wire, 4…20 mA, with head-mounted transmitter
  • Process connection: Conical nozzle (DIN 11851) DN50
  • 0.5…2000 mS/cm; Max. +120°C / +248°F; 10 bar / 145 psi
  • PEEK sensor (FDA and EC1935/2004), with temperature compensation

OPTISENS IND 7000

Inductive conductivity sensor for food and beverage applications

  • For use with analytical transmitter
  • Process connection: Dairy screw (DIN 11851) DN50 and DN65, VARIVENT® N, G1½ or G2 (male, non-hygienic)
  • 0.5…2000 mS/cm; Max. +125°C / +257°F (for SIP/CIP); 10 bar / 145 psi
  • Sterilisable PEEK sensor (FDA and EC1935/2004 conform) with temperature compensation

OPTISENS IND 1000

Inductive conductivity sensor for water, wastewater and chemical applications

  • For use with analytical transmitter
  • Process connection: G1½ union nut and immersion versions
  • 1…2000 mS/cm; Max. +100°C / +212°F
  • Electrodeless conductivity sensor with Pt1000 for temperature compensation

OPTISENS COND 7200

Conductive conductivity sensor for hygienic applications

  • For use with analytical transmitter
  • Process connection: Clamp DN25-40, 1½”
  • 0.05…1000 μS/cm; Max. +135°C / +275°F
  • Short or long version with stainless steel electrodes and Pt100 for temperature compensation

OPTISENS COND 1200

Conductive conductivity sensor for water, wastewater, process water or pure water

  • For use with analytical transmitter
  • Process connection: G½, G¾, G1, ¾ NPT (male)
  • 0.05 μS/cm…20 mS/cm; Max. +135°C / +275°F
  • With two stainless steel, titanium or graphite electrodes and Pt100 for temperature compensation

SMARTPAT COND 7200

Conductive conductivity sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
  • Process connection: VARIVENT® N, Tri-Clamp 1½”, 2″
  • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation

SMARTPAT COND 5200

Conductive conductivity sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male), ¾ NPT (male)
  • 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
  • With graphite electrodes and Pt1000 for temperature compensation

SMARTPAT COND 3200

Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male), ¾ NPT (male)
  • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation

SMARTPAT COND 1200

Conductive conductivity sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male)
  • 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation

OPTISENS ORP 8590

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • -2000…+2000 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt100 temperature sensor

OPTISENS ORP 8500

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode and ceramic diaphragm

SMARTPAT ORP 8150

Potentiometric ORP sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor

SMARTPAT ORP 1590

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • -1500…+1500 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt1000 temperature sensor

OPTISENS PH 9500

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms

OPTISENS PH 9100

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm

OPTISENS PH 8590

Potentiometric pH sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation

OPTISENS PH 8500

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 8390

Potentiometric pH sensor for municipal and industrial wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation

OPTISENS PH 8300

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

SMARTPAT PH 8320

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation

OPTISENS PH 8100

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

SMARTPAT PH 8150

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 1590

Potentiometric pH sensor for potable, process or treated water applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation

SMARTPAT PH 8530

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 8570

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation

SMARTPAT PH 2390

Potentiometric pH sensor for municipal and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation

Water analysis panel

Multi-parameter measuring system for water quality monitoring

  • Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
  • Installation on compact analytical modules: All measuring points at one location
  • Completely pre-wired and pre-assembled for easy bypass installation

SMARTPAT ORP 8510

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor

SENSOFIT RET 5000

Manual retractable assembly for harsh chemical and water treatment applications

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors for high operational safety (exchange, calibration, cleaning without process interruption)
  • Sensor connection: PG13.5; Process connection: Flange DN32, 50 / 1¼”, 2″; G1¼ (male); 1¼ NPT (male)
  • Insertion length: adjustable, max. 720 mm / 28.3″
  • Max. +130°C / +266°F and 12 bar / 174 psi

SENSOFIT RET 5830

Manual retractable assembly for hygienic applications in the food, beverage and pharmaceutical industry

  • For use with Ø12 / 225 mm or Ø0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 107 mm / 4.21″
  • Max. +140°C / +284°F and 16 bar / 232 psi

SENSOFIT INS 7312

Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
  • Sensor connection: PG13.5; Process connection: VARIVENT® N
  • Insertion length: 40 or 45 mm / 1.57″ or 1.77″
  • Max. +140°C / +284°F and 10 bar / 145 psi

SENSOFIT FLOW 2000 C

Flow-through assembly for water and wastewater applications

  • For use with optical oxygen and turbidity sensors OPTISENS ODO and TUR 2000 (inline versions)
  • Sensor connection: union nut; Process connection: hose connection
  • For measurement in small sample streams
  • Max. +50°C / +122°F and 6 bar / 87 psi

SENSOFIT MOUNT 1000

Mounting assembly for applications in various industries

  • For use with retractable or insertion assemblies into pipes and tanks
  • Assembly connection: G1¼ (male); Process connection: Socket weld
  • Straight or inclined version
  • Max. +140°C / +284°F and 16 bar / 232 psi

MAC 300

Liquid analytical transmitter for measurements with OPTISENS TSS, pH/ORP and COND sensors

  • Output: max. 6 x 4…20 mA, max. 6 x relay or optional Modbus
  • Input: up to 3 x sensor
  • -20…+50°C / +4…+122°F (ambient)
  • Robust housing for wall-mount or panel-mount installation

MAC 100

Liquid analytical transmitter for measurements with sensors of the OPTISENS portfolio

  • Output: 3 x 4…20 mA, 3 relays (mechanical)
  • Input: max. 2 x sensor, 2 x temperature
  • -15…+55°C / +5…+131°F (ambient)
  • Robust housing for wall-mount installation

OPTIBRIDGE

USB interface cable for offline calibration and configuration of SMARTPAT sensors

  • For direct communication between a 2-wire or passive 4…20 mA HART® device and a PC
  • With PACTware™ FDT/DTMs for each parameter
  • Different adapter cables available
  • No external power supply required

SD 200

Multiparameter indicator for analytical and other parameters

  • Loop powered, 4…20 mA, with signal calibration feature (passive), HART® 7
  • Indication of multiple units (analytical values, temperature, pressure etc.)
  • With LCD display for wall or rack mount
  • Power supply: 15…30 VDC (loop powered), 2 V voltage drop

SJB 200

Junction box for connecting SMARTPAT to HART® devices

  • Internal connection: Connecting terminals for HART® handhelds
  • External connection: M12 connector
  • With die-cast aluminium housing (IP66)
  • -40…+65°C / -40…+149°F (ambient)

SHD 200

Control unit for 4…20 mA/HART® field devices

  • Second 4…20 mA output for any HART® variable
  • 2 configurable relays for status output, system alarm or limit switch
  • Status signalisation by 5 LEDs according to NAMUR NE 107
  • User-configurable measurement pages for all 4…20 mA and HART® signals incl. trend graph and summary page

SMARTMAC 200

Operating unit for on-site calibration and configuration of SMARTPAT sensors

  • 2-wire loop powered, 4…20 mA/HART® 7
  • Displays main parameter and temperature
  • With sensor exchange function, error and calibration logbooks
  • Also available as hygienic stainless steel and intrinsically safe versions
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
Filter by Categories
Career
News