TCM 0325

The TRICOR CLASSIC Series TCM 0325 Coriolis Mass Flow Meter has a maximum mass flow rate of 325 kg/hr (12 lb/min) or 49 bbl/day and nominal size of DN4 (1/8”), and is rated for process pressures up to 200 bar (2900 psi). Standard accuracy for the TCM 0325 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. The diamond shape (D-shape) tube design has the best overall performance of any Coriolis tube shape. The mechanical advantages of this design include the best signal-to-noise ratio and reduced effects of external vibrations, thus improving zero stability.

Mass Flow Rate (max.):325 kg/h 12 lb/min
Volumetric Flow Rate (max.):325 l/h1.43 gpm, 49 bbl/d (US)
Pressure Rating:200 bar2,900 psi
Nominal Meter Size:DN41/8″

TCM 0650

The TRICOR CLASSIC Series TCM 0650 Coriolis Mass Flow Meter has a maximum mass flow rate of 650 kg/hr (24 lb/min) or 98 bbl/day and nominal size of DN4 (1/8”), and is rated for process pressures up to 200 bar (2900 psi). Standard accuracy for the TCM 0650 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. The diamond shape (D-shape) tube design has the best overall performance of any Coriolis tube shape. The mechanical advantages of this design include the best signal-to-noise ratio and reduced effects of external vibrations, thus improving zero stability.

Mass Flow Rate (max.):650 kg/h24 lb/min
Volumetric Flow Rate (max.):650 l/h2.86 gpm, 98 bbl/d (US)
Standard Pressure Rating:up to 200 bar2900 psi
Nominal Meter Size:DN41/8″

TCM 1550

The TRICOR CLASSIC Series TCM 1550 Coriolis Mass Flow Meter has a maximum mass flow rate of 1550 kg/hr (57 lb/min) or 234 bbl/day and nominal size of DN6 (1/4”), and is rated for process pressures up to 2900 psi (200 bar). Standard accuracy for the TCM 1550 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. The diamond shape (D-shape) tube design has the best overall performance of any Coriolis tube shape. The mechanical advantages of this design include the best signal-to-noise ratio and reduced effects of external vibrations, thus improving zero stability.

Mass Flow Rate (max.):1550 kg/h57 lb/min
Volumetric Flow Rate (max.):1550 l/h6.82 gpm, 234 bbl/d (US)
Standard Pressure Rating:up to 200 bar 2900 psi
Nominal Meter Size:DN61/4″

TCM 3100

The TRICOR CLASSIC Series TCM 3100 Coriolis Mass Flow Meter has a maximum mass flow rate of 3100 kg/hr (114 lb/min) or 468 bbl/day and nominal size of DN6 (1/4”), and is rated for process pressures up to 200 bar (2900 psi). Standard accuracy for the TCM 3100 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. The diamond shape (D-shape) tube design has the best overall performance of any Coriolis tube shape. The mechanical advantages of this design include the best signal-to-noise ratio and reduced effects of external vibrations, thus improving zero stability.

Mass Flow Rate (max.):3100 kg/h114 lb/min
Volumetric Flow Rate (max.):3100 l/h13.65 gpm, 468 bbl/d (US)
Standard Pressure Rating:up to 200 bar2900 psi
Nominal Meter Size:DN61/4″

TCM 5500

The TRICOR CLASSIC Series TCM 5500 Coriolis Mass Flow Meter has a maximum mass flow rate of 5500 kg/hr (202 lb/min) or 830 bbl/day and nominal size of DN15 (1/2”), and is rated for process pressures up to 345 bar (5000 psi). Standard accuracy for the TCM 5500 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.

Mass Flow Rate (max.):5500 kg/h 202 lb/min
Volumetric Flow Rate (max.):5500 l/h24.22 gpm, 830 bbl/d (US)
Standard Pressure Rating:up to 345 bar5000 psi
Nominal Meter Size:DN151/2″

TCM 7900

The TRICOR CLASSIC Series TCM 7900 Coriolis Mass Flow Meter has a maximum mass flow rate of 7900 kg/hr (290 lb/min) or 1193 bbl/day and nominal size of DN15 (1/2”), and is rated for process pressures up to 100 bar (1450 psi). Standard accuracy for the TCM 7900 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.

Mass Flow Rate (max.):7900 kg/h290 lb/min
Volumetric Flow Rate (max.):7900 l/h34.78 gpm, 1193 bbl/d (US)
Pressure Rating:up to 100 bar1450 psi
Nominal Meter Size:DN151/2″

TCM 028K

The TRICOR CLASSIC Series TCM 028K Coriolis Mass Flow Meter has a maximum mass flow rate of 28,000 kg/hr (1029 lb/min) or 4227 bbl/day and nominal size of DN25 (1”), and is rated for process pressures up to 100 bar (1450 psi). Standard accuracy for the TCM 028K is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.

Mass Flow Rate (max.):28,000 kg/h1029 lb/min
Volumetric Flow Rate (max.):28,000 l/h123.3 gpm, 4227 bbl/d (US)
Standard Pressure Rating:up to 100 bar1450 psi
Nominal Meter Size:DN251″

TCM 065K

The TRICOR CLASSIC Series TCM 065K Coriolis Mass Flow Meter has a maximum mass flow rate of 65,000 kg/hr (2388 lb/min) or 9812 bbl/day and nominal size of DN50 (2”), and is rated for process pressures up to 100 bar (1450 psi). Standard accuracy for the TCM 065K is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.

Mass Flow Rate (max.):65,000 kg/h2388 lb/min
Volumetric Flow Rate (max.):65,000 l/h286.2 gpm, 9812 bbl/d (US)
Pressure Rating:up to 100 bar1450 psi
Nominal Meter Size:DN50 2″

TCM 230K

The TRICOR CLASSIC Series TCM 230K Coriolis Mass Flow Meter has a maximum mass flow rate of 230,000 kg/hr (8450 lb/min) or 34,720 bbl/day and nominal size of DN80 (3”), and is rated for process pressures up to 100 bar (1450 psi). Standard accuracy for the TCM 230K is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.

Mass Flow Rate (max.):230,000 kg/h8450 lb/min
Volumetric Flow Rate (max.):230,000 l/h1013 gpm, 34,720 bbl/d (US)
Standard Pressure Rating:up to 100 bar1450 psi
Nominal Meter Size:DN803″

TCE 8000/8100 Coriolis Flow Transmitter – Compact Version

  • Easy interface & factory pre-configured
  • Works out of the box, reduce installation cost
  • Programmable control inputs and outputs
  • Transmits flow rate, total, density or temperature
  • Approvals for us in Hazardous Areas
  • Certified for us in nearly all plant environments

TCE 8000/8100 Coriolis Flow Transmitter – Wall Mount Version

Wall mounted multi-variable Coriolis flow transmitter that can output flow rate, density, and temperature

Outputs available:
Analog current output (up to 2)
Pulse/frequency output (0.5 – 10,000 Hz)
Status output

Programmable control inputs

Interfaces available:
RS485
HART®
Foundation Fieldbus®

LCD Display

Hazardous area approvals:
ATEX
IECEx
cCSAus

TCE 8000 Coriolis Flow Transmitter – Panel Mount Version

Panel mounted multi-variable Coriolis flow transmitter that can output flow rate, density, and temperature

Outputs available:
Analog current output (up to 2)
Pulse/frequency output (0.5 – 10,000 Hz)
Status output

Programmable control inputs

Interfaces available:
RS485
HART®
Foundation Fieldbus®

LCD Display

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
Filter by Categories
Career
News