AF-E 400

Electromagnetic flowmeter for utilities and industrial automation

  • Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
  • Best-in class temperature range, accuracy, pressure drop and flow range
  • Ultra-compact design for parallel installation and tight spaces
  • 4…20 mA, pulse, frequency, Modbus, IO-Link

BATCHFLUX 3100

  • The most compact filling mag meter in the market for filling of conductive liquids, e.g. water, carbonized soft drinks etc.
  • Lightweight, economical design with ceramic flow tube for applications up to 8 bar / 116 psi
  • The DN15 / ½″ ceramic tube conforms to EC1935/2004, FDA, GB 4806
  • Frequency output integrated

BATCHFLUX 5500

  • High accuracy measurement in process batching as well as cold or hot filling of conductive liquids, e.g. milk, fruit drinks with solid content, detergents etc.
  • With ceramic measuring tube and sintered electrodes for applications up to 16 bar / 232 psi
  • Flow tube conforms to EC1935/2004, FDA, GB 4806; 3A certified up to DN25 / 1″
  • Frequency output integrated

OPTIFLUX 1050

Electromagnetic flowmeter for basic applications with conductive liquids

  • Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
  • Extra isolation of electronics for use in high humidity areas
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 1100

Electromagnetic flowmeter for general applications with conductive liquids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 1300

Electromagnetic flowmeter for OEM applications, dosing systems and compact skids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 2050

Electromagnetic flowmeter for basic water and wastewater applications

  • Liner materials resistant to low concentrated chemicals
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 2100

Electromagnetic flowmeter for all standard water and wastewater applications

  • Chemically resistant liner materials
  • Compact version up to IP69, remote version IP68
  • Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 2300

Electromagnetic flowmeter for advanced water and wastewater applications

  • High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
  • 0D/0D installation according to OIML R49 accuracy class 1
  • Flange: DN25…3000 / 1…120″, max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 4050

Electromagnetic flowmeter for basic applications with abrasive and aggressive liquids

  • Chemically resistant liner materials
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN2.5…1200 / ⅒…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 4100

Electromagnetic flowmeter for standard applications with abrasive and aggressive liquids

  • Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…1200 / ⅒…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 4300

Electromagnetic flowmeter for advanced process and custody transfer (CT) applications

  • High accuracy (±0.2%), certified for custody transfer
  • For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
  • Flange: DN2.5…3000 / ⅒…120″, max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 5100

Electromagnetic flowmeter for demanding applications with aggressive and abrasive media

  • With chemically resistant ceramic tube for liquids with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN15…300 / ½…12″, max. PN40 / ASME Cl 300; Sandwich: DN2.5…100 / ⅒…4″
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 5300

Electromagnetic flowmeter for advanced process and master meter applications

  • Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
  • CT: OIML R117, MI-005 etc.
  • Flange: DN15…300 / ½…12″, max. PN40 / ASME Cl 300; Sandwich: DN2.5…100 / ⅒…4″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 6050

  • Cost-effective flow measurement in the food sector
  • Meter size: DN2.5…150 / ⅒…6″ (3A, EHEDG etc.)
  • Many hygienic fittings
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 6100

  • Reliable dosing and filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6″
  • Hygienic fittings and certifications
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 6300

Electromagnetic flowmeter for advanced hygienic applications

  • High accuracy (±0.2%), for exact dosing or filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6″ (3A, EHEDG certified)
  • Many hygienic fittings
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 7300

Electromagnetic flowmeter for low conductivity liquids (≥0.05 μS/cm)

  • Ceramic tube with non-wetted electrodes for extremely adhesive and abrasive media
  • Hygienic and vacuum resistant
  • Flange or wafer/sandwich version: DN25…100 / 1…4″, max. PN40 / ASME Cl:300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

WATERFLUX 3050

Electromagnetic flowmeter for basic water applications

  • Cost-effective measurement of potable, raw and irrigation water
  • Extra isolation of electronics for use in high humidity areas
  • Flange: DN25…600 / 1…24″, max. PN16 / ASME Cl 150; others on request
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

WATERFLUX 3070

Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement

  • Battery- or mains powered, with battery backup option (incl. Modbus)
  • Integrated temperature and pressure measurement for leak monitoring
  • CT: MI-001, OIML R49 up to DN600 / 24″, no inlet/outlet runs needed
  • Burial installation possible (IP68)

WATERFLUX 3100

Electromagnetic flowmeter for standard water applications

  • From raw water measurement to drinking water metering in distribution networks
  • No inlet/outlet runs needed
  • Up to DN600 / 24″, max. PN16 / ASME Cl 150
  • 4…20 mA, pulse, frequency, status, HART®

WATERFLUX 3300

Electromagnetic flowmeter for advanced water applications

  • High accuracy (±0.2%) for water consumption metering and distribution networks
  • No inlet/outlet runs needed
  • CT: MI-001, OIML R49 up to DN600 / 24″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

TIDALFLUX 2300

Electromagnetic flowmeter for applications with partially filled pipes

  • With integrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)
  • Accurate (±1%) and cost-saving alternative to open channel systems
  • Flange: DN200…1600 / 8…64″
  • 3 x 4…20 mA, pulse, HART®, Modbus, PROFINET

FLEXMAG 4050

Electromagnetic flowmeter for single use biopharmaceutical applications

  • With gamma sterilisable disposable flow tube
  • One transmitter accommodates two flow tube diameters
  • Wetted material compliant with ISO 10993 and USP Class VI
  • High accuracy (±1% of MV), wide measuring range, no recalibration

DWM 2000

Electromagnetic insertion-type flowmeter for flow monitoring of conductive media

  • Ideal for liquids, pastes and slurries (≥20μS/cm), suitable for immersed applications (IP68)
  • -25…+150°C / -13…+302°F; up to 25 barg / 360 psig
  • For pipes DN25…400 / 1…16″, optional >DN400 / 16″
  • 3-wire, 4…20 mA

OPTIPROBE

Electromagnetic insertion-type flowmeter for water and wastewater applications

  • With fixed or flexible installation length for hot tapping
  • 0…+100°C; max. 16 barg
  • For pipes ≥DN80 / 3″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 4030

  • Designed and tested for industrial nuclear environments
  • DN25…1000 / 1…40″; with resistant ETFE or PFA liner materials
  • Free of programmable electronic components
  • 4…20 mA

POWERFLUX 4300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With resistant ETFE or PFA liner materials
  • Flange: DN25…1000 / 1…40″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 5030

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube (DN2.5…100 / 1⁄10…4″) for very aggressive and abrasive fluids
  • Free of programmable electronic components
  • 4…20 mA

POWERFLUX 5300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube for very aggressive and abrasive fluids
  • Space-saving wafer design: DN2.5…100 / 1⁄10…4″
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
Generic selectors