OPTISENS PH 9500

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms

OPTISENS PH 9100

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm

OPTISENS PH 8590

Potentiometric pH sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation

OPTISENS PH 8500

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 8390

Potentiometric pH sensor for municipal and industrial wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation

OPTISENS PH 8300

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

SMARTPAT PH 8320

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation

OPTISENS PH 8100

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

SMARTPAT PH 8150

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 1590

Potentiometric pH sensor for potable, process or treated water applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation

SMARTPAT PH 8530

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 8570

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation

SMARTPAT PH 2390

Potentiometric pH sensor for municipal and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation

Water analysis panel

Multi-parameter measuring system for water quality monitoring

  • Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
  • Installation on compact analytical modules: All measuring points at one location
  • Completely pre-wired and pre-assembled for easy bypass installation

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
Filter by Categories
Career
News