Wedge meter

Engineered primary element for DP flow measurement of high viscous and solids-containing fluids

  • Meter run with integrated V-shaped wedge
  • For slurry and fibrous liquids containing solids or gases
  • Reynolds number down to 300
  • Applicable for bi-directional measurement

Cone meter

Engineered primary element for DP flow measurement in applications with limited installation space

  • Meter run with integrated cone and single taps according to EN ISO 5167
  • Rugged solution for difficult media and harsh operating conditions, e.g. in oil and gas applications
  • Designed for large diameters (up to 24″), demanding flow profiles, high pressures and temperatures

Venturi tube

Engineered primary element for DP flow measurement of liquids, gases and steam with the lowest residual pressure loss

  • Machined or welded design (internally machined) according to EN ISO 5167, ASME MFC3
  • Lowest residual pressure loss of all DP elements
  • Only short inlet/outlet runs required
  • From basic to special wet gas applications and high pressure conditions

Flow nozzle

Engineered primary element for DP flow measurement of high velocity, non-viscous or erosive fluids

  • ISA 1932, long radius and Venturi nozzles
  • Standards: ISO 5167, ASME MFC-3M or ASME PTC 6
  • Only short inlet and outlet runs required

OPTIBAR PT 2000

Averaging pitot tube with multiple impact-sensing ports

  • Low pressure loss design; from basic to engineered solutions
  • Cryogenic to high temperatures possible (-200…+1000°C / -328…1832°F); max. 160 bar / 2320.1 psi
  • For line sizes from DN50…2000 / 2…80″ (larger on request)
  • Material: 1.4404 / 316L

OPTIBAR OP 5110

Orifice assembly with measuring flanges (ASME 16.36)

  • With RTJ sealing face and flange taps
  • Size: 1…24″; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 5100

Orifice assembly with measuring flanges (ASME 16.36)

  • With RF sealing face and flange taps
  • Size: 1…24″; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR MR 4300

Orifice meter run with corner taps and annular chambers

  • Completely pre-assembled with orifice plate, piping, inlet/outlet sections, process connections
  • Size: DN15…100 / ½…4″; up to PN100 / ASME Cl 1500
  • Temperature: max. +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 3200

Orifice plate with flat sealing face and corner taps

  • Compact type, with carrier ring, flange plate and optional manifold
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 3100

Orifice plate with flat sealing face and corner taps

  • Separate type, with carrier ring and optional shut-off valve
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24″; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

OPTIBAR OP 1100

Orifice plate with RF sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5, 16.47 A)
  • Size: ½…24″; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

Contact us

OPTIBAR DSP 2000

Diaphragm seal with threaded connection or open measuring flanges

  • Direct or capillary tube attachment to OPTIBAR PM pressure transmitters
  • Thread: G ½ (male), ½ NPT (male, female); Open measuring flanges up to DN50 / 2″
  • Up to +400°C / +752°F (with capillary tube)
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3210

Diaphragm seal with flange design and optional extension

  • Direct and capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4″; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3110

Diaphragm seal with flange design and optional extension

  • Capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4″; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3100

Diaphragm seal with flange design and optional extension

  • Direct attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4″; max. PN63 / ASME Cl 300
  • Up to +150°C / +302°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DP 7060

High performance DP transmitter with integrated line pressure measurement
Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 400 bar / 5800 psi
Reference accuracy of ±0.065%
2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

OPTIBAR DP 3050

The most compact design in its class
Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
Reference accuracy ± 0.1%
2-wire, 4…20 mA/HART®7

OPTIBAR DSP 3000

Diaphragm seal with flange design and optional extension

  • For direct or capillary tube attachment to OPTIBAR PM pressure transmitters
  • Flange: DN50…100 / 2…4″; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F (with capillary tube)
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3220

Diaphragm seal with flange design and optional extension

  • 2 x capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4″; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR OP 4100

Separate type, for installation between standard flanges (EN 1092-1), optional shut-off valves
Size: DN50…600; up to PN100
Temperature: up to +400°C / +752°F
Material: 1.4404 / 316L

Venturi tube

Machined or welded design (internally machined) according to EN ISO 5167, ASME MFC3
Lowest residual pressure loss of all DP elements
Only short inlet/outlet runs required
From basic to special wet gas applications and high pressure conditions

OPTIBAR PC 5060

Pressure transmitter for advanced process pressure and level applications

  • Robust design, with corrosion and abrasion resistant ceramic diaphragm
  • 25 mbar…100 bar / 0.73…1450 psi; max. +150°C / +302°F
  • Various threads, flanges, hygienic and other connections
  • 2-wire, 4…20 mA, HART®, FF, Profibus-PA, Bluetooth®

OPTIBAR PM 5060

Pressure transmitter for process pressure and level applications

  • Rugged design with fully welded metallic diaphragm suited to high pressure ranges and hygienic requirements
  • 100 mbar…1000 bar / 1.45…14500 psi
  • Various threads, flanges, aseptic and other connections
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

OPTIBAR PM 3050

Pressure transmitter for general pressure and level applications

  • Compact design with recessed or flush metallic diaphragm and optional display module
  • 0.1…100 bar / 1.45…1450 psi
  • Thread: G½, ½ NPT (male, female)
  • 2-wire 4…20 mA/HART®

OPTIBAR P 2010

Pressure transmitter for hygienic pressure and level applications

  • Ultra-compact design with flush diaphragm: with 3A certification
  • 0.1…40 bar / 4…580 psi; max. +150°C / +302°F (for SIP/CIP)
  • Many hygienic connections available
  • 2-wire 4…20 mA

OPTIBAR PSM 2010

Pressure switch for hygienic level and pressure applications

  • Integrated display with switch state indication and 2-button setup
  • 0.1…40 bar / 4…580 psi; max. +150°C / +302°F (for SIP/CIP)
  • With many flush-mounted hygienic process connections, also 3A certified
  • Fully configurable: IO-Link and PNP/NPN as standard I/O, 4…20 mA, 0…10 V or NPN/PNP as secondary output

OPTIBAR PSM 1010

Pressure switch for basic pressure and level applications

  • Integrated display with switch state indication and 2-button setup
  • 0.1…600 bar / 1.5…8700 psi; max. +125°C / +257°F
  • With recessed stainless steel diaphragm
  • Fully configurable: IO-Link and PNP/NPN as standard I/O, 4…20 mA, 0…10 V or NPN/PNP as secondary output

OPTIBAR LC 1010

Submersible level probe for water and wastewater applications

  • For continuous hydrostatic level measurement in basins and wells
  • With corrosion-resistant ceramic measuring cell
  • Level (water): 1…20 m / 3.3…65.6 ft; Pressure: 0.1…10 bar / 1.45…145 psi
  • 2-wire, 1 x 4…20 mA, HART®

OPTIBAR P 1010

Pressure transmitter for basic pressure and level applications

  • Ultra-compact design with recessed stainless steel diaphragm
  • Up to 600 bar / 8700 psi
  • Thread: ¼, ½ NPT (male); G¼, G½ (male)
  • 2-wire 4…20 mA
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
product
Filter by Categories
Career
News